Three Phase Soft Starters

Three phase soft starters offer diagnostic monitoring of line, load & supply as well as normal operational status. Full control of the three phases enables better balance and less interference. These soft starters are suitable for AC motor control, incandescent or infrared lamp starting, loaded transformer control and other loaded control applications. Contact us on 03 9720 4522 or sales@practicalcontrol.com.au with any enquiries.

SMCV6080 picture

SMCV6080 Soft Starter

Pmax motor 400VAC
Pmax motor 230VAC
Max current AC53a
Max current EN60947-4-2
Y*: 7.5kW | D*: 13kW
Y*4.3kW I D*7.5kW
16A
11.5A

* The star assembly (Y) corresponds to in-line wired starter. The delta assembly (D) corresponds to the starter wired in the triangle coupling of the motor. Each channel is wired in series with a winding of the motor.

SMCV6110 picture

SMCV6110 Soft Starter

Pmax motor 400VAC
Pmax motor 230VAC
Max current AC53a
Max current EN60947-4-2
Y*:11kW I D*7.5kW
Y*:6.4kW I D*11kW
25A
15.5A

* The star assembly (Y) corresponds to in-line wired starter. The delta assembly (D) corresponds to the starter wired in the triangle coupling of the motor. Each channel is wired in series with a winding of the motor.

SMCV6150 picture

SMCV6150 Soft Starter

Pmax motor 400VAC
Pmax motor 230VAC
Max current AC53a
Max current EN60947-4-2
Y*: 15kW | D*: 26kW
Y*: 8.6kW | D*: 15kW
30A
22.5A

* The star assembly (Y) corresponds to in-line wired starter. The delta assembly (D) corresponds to the starter wired in the triangle coupling of the motor. Each channel is wired in series with a winding of the motor.

SMCW6020 picture

SMCW6020 Soft Starter

Pmax motor 400VAC
Pmax motor 230VAC
Max current AC53a
Max current EN60947-4-2
Y*: 2.5kW | D*: 4.3kW
Y*: 1.4kW | D*: 2.5kW
5.6A
4A

* The star assembly (Y) corresponds to in-line wired starter. The delta assembly (D) corresponds to the starter wired in the triangle coupling of the motor. Each channel is wired in series with a winding of the motor.

SMCW6080 picture

SMCW6080 Soft Starter

Pmax motor 400VAC
Pmax motor 230VAC
Max current AC53a
Max current EN60947-4-2
Y*: 7.5kW | D*: 13kW
Y*: 4.3kW | D*: 7.5kW
16A
11.5A

* The star assembly (Y) corresponds to in-line wired starter. The delta assembly (D) corresponds to the starter wired in the triangle coupling of the motor. Each channel is wired in series with a winding of the motor.

SMCW6110 picture

SMCW6110 Soft Starter

Pmax motor 400VAC
Pmax motor 230VAC
Max current AC53a
Max current EN60947-4-2
Y*: 11kW | D*: 19kW
Y*: 6.4kW | D*: 11kW
25A
15.5A

* The star assembly (Y) corresponds to in-line wired starter. The delta assembly (D) corresponds to the starter wired in the triangle coupling of the motor. Each channel is wired in series with a winding of the motor.

SMCW6150 picture

SMCW6150 Soft Starter

Pmax motor 400VAC
Pmax motor 230VAC
Max current AC53a
Max current EN60947-4-2
Y*: 15kW | D*: 26kW
Y*: 8.6kW | D*: 15kW
30A
22.5A

* The star assembly (Y) corresponds to in-line wired starter. The delta assembly (D) corresponds to the starter wired in the triangle coupling of the motor. Each channel is wired in series with a winding of the motor.

SMCW6151 picture

SMCW6151 Soft Starter

Pmax motor 400VAC
Pmax motor 230VAC
Max current AC53b
Max current EN60947-4-2
Y*: 15kW | D*: 26kW
Y*: 8.6kW | D*: 15kW
30A (AC53b)
22.5A (AC53b)

* The star assembly (Y) corresponds to in-line wired starter. The delta assembly (D) corresponds to the starter wired in the triangle coupling of the motor. Each channel is wired in series with a winding of the motor.